Extrusion line inside a rubber components plant, profiles running through inline tooling stations
01 · CONSTRUCTION & INFRASTRUCTURE

Rubber That Seals a Building Against Water, Wind and Movement.

Extruded EPDM glazing and weatherseal profiles, cellular expansion joint seals, building-services gaskets and vibration mounts for plant — extruded and moulded to your drawing at our ISO 9001:2015 plant in Nashik. Compounded in-house, so the ozone and UV resistance a facade needs for twenty years is formulated rather than bought in.

  • ISO 9001:2015
  • EPDM · OZONE & UV
  • EXTRUDED & MOULDED

02 · PRODUCTS

Seven Product Lines on One Project

  • Extrusion Profiles

    Glazing gaskets, wedge and H-sections, door and window weatherseals, cabinet and shutter seals. Die cut in-house, so a non-standard section is a drawing rather than a compromise.

  • Sponge & Foam Rubber

    Facade and curtain-wall expansion joints, closed-cell backing, self-adhesive foam tape, acoustic isolation pads.

  • Gaskets

    Flange and body gaskets for building-services pipework, pumps, tanks and plant.

  • Anti-Vibration Mounts

    Isolation for chillers, air-handling units, generator sets and pumps — the plant that transmits structure-borne noise into a building.

  • O-Rings

    Building-services pipework, valves, pumps and fire-main couplings.

  • Rubber Lining & Skirting

    Tank, sump and pipework lining for water and effluent plant on infrastructure projects.

  • Bonded Components

    Bonded acoustic and vibration pads where the rubber is vulcanised to a steel plate rather than glued to it.

03 · APPLICATIONS

Six Places a Building Needs Rubber

  • Facade and curtain wall

    Structural glazing gaskets, wedge and setting-block sections, weather seals and cellular expansion joint fillers. Corner mouldings vulcanised to the profile so the joint is not a butt splice on site.

    CompoundEPDM

  • Windows, doors and shutters

    Extruded weatherseal profiles, bubble and fin sections, glazing beads and cabinet seals.

    CompoundEPDM · CR

  • Roof and waterproofing

    Self-adhesive closed-cell tape, upstand and penetration seals, membrane termination tape.

    CompoundEPDM · CR

  • Plant rooms and services

    Anti-vibration mounts and acoustic pads under chillers, AHUs and gensets; flange gaskets and O-rings on services pipework.

    CompoundNR · Neoprene · NBR

  • Below ground and wet areas

    Pipe penetration seals, sump and tank lining, coupling and manhole gaskets.

    CompoundEPDM · NR

  • Structural movement

    Expansion and movement joint seals in dense and cellular section, sized to the joint’s designed range rather than its installed gap.

    CompoundEPDM · CR

04 · COMPOUND

On a Facade, Ozone Decides Before Temperature Does

External seals fail by ozone cracking and UV embrittlement, not by reaching a temperature limit. A twenty-year facade seal spends its life between −5 and +65 °C and still perishes, because sunlight and atmospheric ozone attack the polymer backbone. Every compound we mix is available; these are ranked for building duty.

If the duty isCompoundService temperatureNote
External — facade, glazing, roof, weathersealEPDM−40 to +140 °CThe default for anything exposed. Outstanding ozone, UV and water resistance; tested to ISO 1431-1. Never where oil or fuel is present
Structural movement, acoustic and vibration padsNatural rubber−20 to +90 °CBest damping and flex-fatigue of the eight, which is what a load-bearing pad needs. Protected positions only — poor ozone resistance
Marine and coastal exposure, moderate oil, flame-retardant gradesNeoprene−40 to +120 °CThe compromise where salt air, some oil and a flame-retardant grade are all wanted at once
Plant-room pipework carrying oil, fuel or hydraulic fluidNBR−30 to +120 °CGenerator fuel lines and hydraulic plant. Never on a facade — nitrile has poor ozone resistance and will craze in sunlight
High-temperature services, flue and boiler-room gasketingSilicone−60 to +220 °CWhere temperature genuinely governs. Low tear strength, so not for a section that is stretched over a frame
Abrasive water, low-cost protected dutySBR−30 to +100 °CInternal and protected positions only. No exposure, no oil
Aggressive chemistry in effluent or process plantFKM−20 to +250 °C continuous to +200 °CRarely justified on a building. Specify on the medium, not the temperature
Hot oil and oil mistAEM−40 to +175 °C continuous to +160 °CRarely a construction duty. Listed because every compound is available

Dimensional Standards, Not Approvals

StandardCoversOur position
ASTM C864Dense elastomeric compression seal gaskets, setting blocks and spacers — the solid glazing sectionsWe mould and extrude to it
ASTM C509Elastomeric cellular preformed gasket and sealing material — the sponge glazing sectionsWe extrude to it
ASTM C1115Dense elastomeric silicone rubber gaskets and accessoriesWhere silicone is specified
IS 5382Rubber sealing rings for gas mains, water mains and sewersSupplied — see /industries/water-fluid-management
EN 681-1Elastomeric seals for water supply and drainage pipe jointsSupplied
ASTM D2000Line-callout classification for the compound itselfWe quote against a callout if you have one
ISO 3302-1Dimensional tolerances — class E1–E3 extruded, M1–M4 mouldedTolerance follows the section
ISO 1431-1Ozone resistance test methodTested at our NABL partner laboratory
IRC:83 · IS 15462 · EN 1337-3Structural elastomeric bearingsNot held. See section 06
IS 3809 · BS 476 · EN 1366Fire resistance of building elementsNot held. See section 06

Four Things We Will Not Quote

Rubber appears in parts of a building where the product is not really rubber, it is a certified assembly. We would rather tell you now than at qualification.

Not suppliedWhyWhat we can do
Laminated elastomeric bridge bearingsA structural product type-tested and load-certified to IRC:83 Section IX, IS 15462 or EN 1337-3. We hold no structural product approval and a bearing sits under a deck.Plain rubber bearing pads and acoustic isolation pads for non-structural duty, quoted against your load and area
Fire-rated and intumescent sealsA fire rating is certified against a specific tested assembly by a third-party laboratory to IS 3809, BS 476 or EN 1366. A flame-retardant compound is not a fire rating and we will not let the two be confused.Flame-retardant neoprene grades where the specification asks for a compound property rather than a tested assembly. Third-party testing arranged on request
EPDM roofing membrane systemsSingle-ply roofing is a warranted system with installer certification behind it. The warranty is the product.Closed-cell EPDM tape, upstand and penetration seals, and termination detailing that goes with someone else’s membrane
PVC waterstopsPVC is not a vulcanised rubber and we do not extrude it — the same reason we decline polyurethane liners and polyurethane hydraulic seals.Rubber waterstops and construction-joint seals in EPDM or natural rubber, where the specification permits them

ISO 9001:2015 · Certificate 09111526A

Integral Certification Ltd · Valid to 21 February 2027

Scope: rubber moulded components — quality management, not a product approval

IATF 16949 — upgrade in progress, certification targeted by end 2026

ISO 14001 and ISO 45001 — targeted 2027

FREQUENTLY ASKED QUESTIONS

Technical & commercial questions

09 · ENQUIRIES

Request a Construction Quotation

Send the section drawing and the annual metreage, or the moulded part drawing and the quantity. Tell us whether the position is external or protected — that single answer decides the compound before anything else does. Our engineering team responds within 48 hours with a compound recommendation, dimensional confirmation and a quotation.